FLAMEX® PANTO LEAD-FREE 185mm²

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50264-1; IEC 60502

For inside and outside use in railway vehicles. Installation in cable ducts or tubes.

Available on request: HV loop, completely pre-assembled flexible cables with plugs and sealing ends, electrically tested.

 

DESIGN

1. Conductor: Flexible stranded tinned copper, class 5 acc. to IEC 60228

2. Inner semi-conductive layer: Conductive rubber

3. Insulation: Cross-linked compound type EI 110 acc. to EN 50264-1

4. Outer conductive layer: Conductive rubber easy to strip

5. Screen: Conductive tape + tinned single wires with separator

6. Outer sheath: Cross-linked compound type EM104  acc. to EN 50264-1. Oil, diesel, ozone and UV resistant. Colour: black

 

Example of cable marking: FLAMEX PANTO – LEAD FREE - 1x [conductor nominal cross section] / [geometrical screen cross-section] 26/45kV I LYNXEO I WEEK/YEAR batch-no

FIRE SAFETY STANDARDS

FLAMEX® HV Power cables are conform to EN 45545-2


GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 5 x outer cable diameter
    • For installation and occasional movements: 10 x outer cable diameter

Characteristics

Characteristics

구조적 특성

구조적 특성

도체 재료
Tin plated copper
Conductor flexibility
소프트 레벨 5
Material of the inner semi-conductor
conductive rubber
절연
Cross-linked compound
Material of the external semi-conductor
Conductive rubber
스크린
Tin plated copper wires
피복
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2

치수

치수

도체 단면적
185 mm²
Screen section
25 mm²
Diameter over external semi-conductor
37.0 mm
Minimum outer diameter
42.0 mm
Maximum outer diameter
44.0 mm
무게(근사치)
3600 kg/km

전기적 특성

전기적 특성

정격전압 Uo/U (Um)
26 / 45 (54) kV
Maximum operating voltage
32 kV

사용 특성

사용 특성

난연
EN 60332-1-2
Fire retardant
IEC 60332-3-24 (cat C)
연기밀도
EN/IEC 61034-2
유독가스
EN 50305-9.2
操作温度范围
-40 ... 90 °C
Fire load
- kWh/m
Minimum operating temperature
- °C
Short-circuit max. conductor temperature
200 °C
Oil resistance
Yes
Ozone resistance
Yes
U.V resistance
Yes

Resources

Resources

Documentation

xls — 0 B
xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close